Lompat ke konten Lompat ke sidebar Lompat ke footer

kode error ac aux lengkap dengan penjelasan

 Salam rekan-rekan pendingin


kali
ini saya akan membagikan informasi mengenai kode error AC
AUX,berdasarkan pengalaman di lapangan dan forum teknisi ketika
menangani kode error tersebut. semoga bisa membantu rekan-rekan dalam
mengidentifikasi kode error AC AUX dan melakukan perbaikan dengan tepat.


berikut penjelasannya








kode error ac aux
kode error ac aux


kode error ac aux dan penjelasannya



1.HS(Y) HSA(Y) HSB(Y) HSF (Y) HV(Y) HVA(Y) digital display for the series air-conditioner faults:





kode error ac aux E4 : PG motor feedback is abnormal. The display precedence level: 1


- Kode error ac aux E1 : Plastic temp sensor is abnormal. The display precedence level: 2


- kode error ac aux E3 : Copper temp sensor is abnormal (indoor). The display precedence level: 3


- kode error ac aux E2 : Copper temp sensor is abnormal (outdoor). The display precedence level: 4





2. H (Except KFR-25G/H) H1 HA HB series faults display:



  • Fault source: PG motor feedback is abnormal

  • Display mode: Timing light twinkles 4 times in every 8 seconds

  • The display precedence level: 1

  • Fault source: Plastic temp sensor is abnormal

  • Display mode: Timing light twinkles 1 times in every 8 seconds

  • The display precedence level: 2

  • Fault source: Copper temp sensor is abnormal (indoor)

  • Display mode: Timing light twinkles 2 times in every 8 seconds

  • The display precedence level: 3

  • Fault source: Copper temp sensor is abnormal (indoor)

  • Display mode: Timing light twinkles 1 times in every 1 seconds

  • The display precedence level: 4


3. H(Y) Model air conditioner fault display:





  • Fault source: PG motor feedback is abnormal

  • Display mode: Timing light twinkles 4 times in every 8 seconds

  • The display precedence level: 1












  • Fault source: Plastic temp sensor is abnormal

  • Display mode: Timing light twinkles 1 times in every 8 seconds

  • The display precedence level: 2







  • Fault source: Copper temp sensor is abnormal (indoor)

  • Display mode: Timing light twinkles 2 times in every 8 seconds

  • The display precedence level: 3






  • Fault source: Copper temp sensor is abnormal (outdoor)

  • Display mode: Timing light twinkles 1 times in every 1 seconds

  • The display precedence level: 4


4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac faults:





kode error ac aux E4 : PG motor feedback is abnormal


- kode error ac aux E1 : Plastic temp sensor is abnormal


- kode error ac aux E3 : Copper temp sensor is abnormal (indoor)





5. All of the other E series except EA EC EM EY EZ EAA EAD:





  • Fault source: PG motor feedback is abnormal

  • Display mode: Timing light twinkles 4 times in every 8 seconds

  • The display precedence level: 1












  • Fault source: Plastic temp sensor is abnormal

  • Display mode: Timing light twinkles 1 times in every 8 seconds

  • The display precedence level: 2







  • Fault source: Copper temp sensor is abnormal (indoor)

  • Display mode: Timing light twinkles 2 times in every 8 seconds

  • The display precedence level: 3



6. QA QB QD digital display series ac faults:


  • Fault source: PG motor feedback is abnormal

  • Display mode: E4

  • The display precedence level: 1






  • Fault source: Plastic temp sensor is abnormal

  • Display mode: E1

  • The display precedence level: 2






  • Fault source: Copper temp sensor is abnormal

  • Display mode: E3

  • The display precedence level: 3






  • Fault source: Over-current oprotection

  • Display mode: E6

  • The display precedence level: 4



7. QC QQ light display series air-conditioner faults:


  • Fault source: PG motor feedback is abnormal

  • Display mode: Timing light twinkles 4 times in every 8 seconds

  • The display precedence level: 1






  • Fault source: Plastic temp sensor is abnormal

  • Display mode: Timing light twinkles 1 times in every 8 seconds

  • The display precedence level: 2






  • Fault source: Copper temp sensor is abnormal

  • Display mode: Timing light twinkles 3 times in every 8 seconds

  • The display precedence level: 3






  • Fault source: Over-current oprotection

  • Display mode: Timing light twinkles 6 times in every 8 seconds

  • The display precedence level: 4




baca juga  kode error ac LG smart inverter





8. Faults display of 18000BTU~24000BTU wall unit series ac non-digital tube displays:


  • Fault source: PG motor feedback is abnormal

  • Display mode: Timing light twinkles 1 times in every 8 seconds

  • The display precedence level: 2

  • appearance: System turns off






  • Fault source: Plastic temp sensor is abnormal

  • Display mode: Timing light twinkles 2 times in every 8 seconds

  • The display precedence level: 3

  • appearance: System turns off






  • Fault source: Copper temp sensor is abnormal

  • Display mode: Timing light twinkles 8 times in every 8 seconds

  • The display precedence level: 4

  • appearance: System doesn’t turns off



Digital tube displays:


  • Fault source: PG motor feedback is abnormal

  • Display mode: E1

  • The display precedence level: 2

  • appearance: System turns off



  • Fault source: Plastic temp sensor is abnormal

  • Display mode: E3

  • The display precedence level: 3

  • appearance: System turns off






  • Fault source: Copper temp sensor is abnormal

  • Display mode: E2

  • The display precedence level: 4

  • appearance: System doesn’t turn off






  • E1: Temperature sensor of air intake fault

  • E2: Temperature sensor of outdoor coil fault

  • E3: Temperature sensor of indoor coil fault

  • E4: PG motor of indoor unit feedback fault





kode error ac split merk aux






Self-check information: Hint to defrosting






  • Self-check code of luminotron: Flicker 1 time/1s

  • Digital self-check code: Indicates “dF“or defrosting indicator displays





Self-check information: Hint to defense against cold wind



  • Self-check code of luminotron: Flicker 1 time/3s

  • Digital self-check code: Fan motor picture not running



Self-check information: Failure of room temperature sensor


  • Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)

  • Digital self-check code: E2/(L2)



Self-check information: Failure of coiled pipe sensor


  • Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)

  • Digital self-check code: E3/(L1)



Self-check information: Abnormality of outdoor unit


  • Self-check code of luminotron: Flicker 4 times/6s (luminating)

  • Digital self-check code: E4/(E5)



Self-check information: Without feedback of internal fan motor


  • Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)

  • Digital self-check code: E5/(L6)



Self-check information: Zero crossing signal without current


  • Self-check code of luminotron: Flicker 6 times/8s

  • Digital self-check code: E6



Self-check information: External feedback failure


  • Self-check code of luminotron: Flicker 7 times/9s

  • Digital self-check code: E7



Self-check information: Overheat protection


  • Self-check code of luminotron: Flicker 8 times/10s

  • Digital self-check code: E8



Self-check information: Water pump failure


  • Self-check code of luminotron: Flicker 9 times/11s

  • Digital self-check code: E9





kode error ac aux
Aux AC Error Codes and Troubleshooting


Troubleshooting Guide



Problem: The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on


Cause: Since
the air-conditioner is powered on, it will come to working condition as
long as you press the ON/OFF button of the remote control and the
signal is well received.


Problem: The
compressor stops running but the indoor fan motor keeps working when it
is at cooling mode with the indoor temperature higher than set
temperature.


Cause: If
you turn off the air-conditioner and restart it immediately, it will
return to normal in 3 minutes, after that, the air-conditioner will
automatically adjust the indoor fan speed to what you set.


Problem: The compressor works discontinuously at dehumidifying mode.


Cause: The air-conditioner will automatically control the working of the compressor according to the inside temperature


Problem: The air-conditioner dose not work while the LED display is on.


Cause: The
TIMER is set with the air-conditioner,it will be in hold on condition.
If the TIMER setting is cancelled, the air-conditioner will return to
normal working condition.


Problem: The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.


Cause: The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.






Posting Komentar untuk "kode error ac aux lengkap dengan penjelasan"

close